Shenzhen Zeus Technology Co., Ltd.
Main products:Auto Code Reader,Battery Analyzer,ECU Sensor Simulation,Multimeter
Products
Contact Us
  • Contact Person : Ms. Deng Mandy
  • Company Name : Shenzhen Zeus Technology Co., Ltd.
  • Tel : 86-755-83266856-8009
  • Fax : 86-755-83266856
  • Address : Guangdong,Shenzhen,Room 1208-1217, 12/F,zhonghao building,Ba Gua Forth RD,Futian,Shenzhen,China
  • Country/Region : China
  • Zip : 518029

Automotive Emission exhaust GAS Analyzer(4-Gas - Portable)MST-406EN

Automotive Emission exhaust GAS Analyzer(4-Gas - Portable)MST-406EN
Product Detailed
One year guarantee Quick shipment Best service Good price

MST-406EN Automotive Emission Analyzer(4-Gas / Portable)

Main Features and Specifications

1. Measure concentration of HC, CO, CO2, O2 contained in exhaust gases from gasoline engine of vehicles. Advanced NDIR (non-Dispersive Infrared) analysis technology is used to measure HC, CO, CO2 and the newest generation of electrochemical technology is adopted to measure O2 . Designed with LCD screen for easier setting and operation.

2. Automatic calculation and display of A/F (air-fuel-ratio)

and Lambda air ratio λ.

3. Emissions from vehicle engine fuels of CNG, LPG and Ethanol gasoline can be measured.

4. Small Size, light weight and most convenient for carry.

5. Designed with inductive clip-on pickup sensor for RPM

measurement.

6. Designed with oil temperature measurement probe.

6. Designed with RS-232C digital serial interface.

7. 200 groups of measurement data storage and review.

8. In compliance with accuracy requirement of ISO 3930

or OIML R99 Class I.

 

Options and Accessories:

1. Micro printer.

2. Various RPM measurement adaptors.

3. DC12V vehicle power inverter.

 

Main Technical Specifications

Measuring Range:

HC: 0~9,999 ppm (n-Hexane)

CO: 0~10 %

CO2 : 0~18 % 2

O2 : 0~25 % 2

 

Measurement Accuracy:

HC: ±12 ppm (abs.) 0~2,000 ppm

±5 % ( rel. ) 0~2,000 ppm (which ever is larger)

±10 % ( rel. ) 2,001~9,999 ppm

CO: ±0.06 % (abs.)

±5 % ( rel. ) (which ever is larger)

CO2 : ±0.5 % (abs.)

±5 % ( rel. ) (which ever is larger)

O2 : ±0.1 % (abs.)

±5 % ( rel. ) (which ever is larger)

Response Time: Less than 10s for T90

(O2, less than 12s)

Warm-up Time: 10 min.

(ambient temperature is not lower than 20°C)

Power Supply: AC220V ±10% 50Hz ±1Hz

Net Weight: 6.0Kg

Outer Dimension:

260mm(W) × 180mm(H) × 450mm(D)

 

Automotive Emission exhaust GAS Analyzer(4-Gas - Portable)MST-406EN



Copyright Notice @ 2008-2022 ECVERY Limited and/or its subsidiaries and licensors. All rights reserved.